MAIN AND ALTERNATOR CIRCUIT BREAKER REPLACEMENT

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  255    256    257    258    259  260  261    262    263    264    265  
img
. .
TM 5-2410-240-23-3
0199
INSTALLATION CONTINUED
2. Install solenoid valve (Figure 3, Item 1) on demand fan manifold (Figure 3, Item 2). Torque solenoid valve to
18 2 lb-ft (24 3 Nm).
Figure 3. Demand Fan Manifold.
0199
END OF TASK
FOLLOW-ON TASKS
000199
1. Install demand fan manifold on machine (WP 0198).
2. Check hydraulic fluid (WP 0160).
3. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE