Figure 3. Demand Fan Manifold.
Figure 2. Fuse Panel Side Cover.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  256    257    258    259    260  261  262    263    264    265    266  
img
. . . . . . . .
12
TM 5-2410-240-23-3
0200
FIELD MAINTENANCE
-
MAIN AND ALTERNATOR CIRCUIT BREAKER REPLACEMENT
0
200
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-240-10)
0
(WP 0289, Item 51)
Seat air suspension removed (WP 0241)
0
0
Outer batteries removed (WP 0142)
Materials/Parts
0
0
Rag, wiping (WP 0290, Item 21)
Drawings Required
0
0
Tag, marker (WP 0290, Item 30)
TM 5-2410-240-24P, Figure 68
0
0
Tiedown strap (WP 0290, Item 31)
0
Estimated Time to Complete
0
References
1.0 Hr
0
0
WP 0282
0
REMOVAL
000200
1. Remove fire extinguisher (TM 5-2410-240-10).
2. Remove three bolts (Figure 1, Item 3), washers (Figure 1, Item 2), and bracket (Figure 1, Item 5) from cover
(Figure 1, Item 1).
3. Remove four bolts (Figure 1, Item 6), washers (Figure 1, Item 4), and cover (Figure 1, Item 1) from machine.
Figure 1. Fuse Panel Front Cover.