TM 5-2410-240-23-3
0201
REMOVAL CONTINUED
19. Rotate collar (Figure 8, Item 2), and disconnect harness (Figure 8, Item 1) from connector (Figure 8, Item 6).
20. Remove nut (Figure 8, Item 5) and washer (Figure 8, Item 4) from connector (Figure 8, Item 6).
21. Push connector (Figure 8, Item 6) inside circuit box (Figure 8, Item 3).
Figure 8. Harness Tiedown Straps.
0201
22. Position harness (Figure 9, Item 1) outside circuit box (Figure 9, Item 5).
23. Remove two bolts (Figure 9, Item 3), washers (Figure 9, Item 4), and magnetic switch (Figure 9, Item 2) from
circuit box (Figure 9, Item 5).
Figure 9. Magnetic Switch Mounting.
0201