Figure 8. Harness Tiedown Straps.
CLEANING AND INSPECTION

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  275    276    277    278    279  280  281    282    283    284    285  
img
.
TM 5-2410-240-23-3
0201
REMOVAL CONTINUED
N OT E
Tag and mark electrical cables to aid installation.
24. Remove two nuts (Figure 10, Item 5) and four cables (Figure 10, Item 4) from magnetic switch (Figure 10,
Item 6).
N OT E
Note location of each circuit breaker and fuse to aid installation.
25. Remove 4 circuit breakers (Figure 10, Item 1) and 28 fuses (Figure 10, Item 2) from 2 fuse boxes
(Figure 10, Item 3).
Figure 10. Magnetic Switch Cables.
0201
END OF TASK