Figure 10. Fuse #5.
Table 1. Powertrain Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  472    473    474    475    476  477  478    479    480    481    482  
img
. . . . . . .
TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
299-8 Transmission Lever
39. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
Position Sensor Out of
0296), test for continuity between
to step 40.
Range - Continued
pin 3 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C3 (WP 0018, Figure 21)
form harness (WP 0209) and
and all other pins in platform har-
instrument panel harness (WP
ness connector MA-C3 (WP 0018,
0260). Replace Fuse #5 (TM 5-
Figure 21).
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
40. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 41.
pin 3 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C3 (WP 0018, Figure 21)
form harness (WP 0209) and
and machine ground.
instrument panel harness (WP
0260). Replace Fuse #5 (TM 5-
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
41. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 42.
pin 6 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C14 (WP 0018, Figure 33)
form harness (WP 0209) and
and all other pins in platform har-
instrument panel harness (WP
ness connector MA-C14 (WP
0260). Replace Fuse #5 (TM 5-
0018, Figure 33).
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
42. Using a digital multimeter (WP
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 43.
pin 6 on platform harness connec-
2. If continuity is found, replace plat-
tor MA-C14 (WP 0018, Figure 33)
form harness (WP 0209) and
and machine ground.
instrument panel harness (WP
0260). Replace Fuse #5 (TM 5-
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).