TM 5-2410-241-23-1
0031
STARTING SYSTEM TESTS CONTINUED
Test Step 4. Measure Voltage to Starter and Starting Motor Solenoid.
00031
1. Position boot (Figure 3, Item 3) aside to access starter motor positive terminal (Figure 3, Item 1) and starting
motor solenoid S terminal (Figure 3, Item 2).
2. Monitor and record the digital multimeter and measure voltage between the starter motor positive terminal
(Figure 3, Item 1) and ground.
a. If voltage is 17 to 26 volts, proceed to step 3.
b. If voltage is less than 17 volts, perform Battery Cables and Alternators Cables Test (WP 0029).
3. With assistance, monitor and record the digital multimeter and measure voltage between the starting motor
solenoid S terminal (Figure 3, Item 2) and ground while attempting to crank the engine (TM 5-2410-241-10).
a. If voltage is 17 to 26 volts, replace starter motor (WP 0061).
b. If voltage is less than 17 volts, proceed to Test Step 5.
Figure 3. Measuring Voltage at Starter.
0031