• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
High Pressure Cutoff Test
A/C PERFORMANCE: TEST

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1006    1007    1008    1009    1010  1011  1012    1013    1014    1015    1016  
img
. .
4
TM 5-2410-241-23-1
0036
FIELD MAINTENANCE
-
A/C AND HEATING TESTS, INSPECTIONS, AND ADJUSTMENTS
0
036
Refrigerant System: Evacuate, Refrigerant Leakage: Test,
Refrigerant System: Charge, A/C Performance: Test
INITIAL SETUP
Tools and Special Tools
Personnel Required
0
0
Tool Kit, General Mechanic's (WP 0302, Item
91C10
0
65)
91L10
0
0
Adapter Kit Test (WP 0302, Item 5)
0
References
0
Software Kit (Mil ET) (WP 0302, Item 55)
0
WP 0044
Remover, Electrical Contact, Red (WP 0302,
0
WP 0096
Item 47)
0
0
WP 0220
Test Set, Electronic (MSD) (WP 0302, Item
0
WP 0263
62)
0
0
Tool Kit, Service, Refrigeration, Ordnance
Equipment Condition
0
(WP 0302, Item 66)
0
Machine parked (TM 5-2410-241-10)
0
Materials/Parts
0
Rag, Wiping (WP 0303, Item 24)
0
REFRIGERANT SYSTEM: EVACUATE
00036
Evacuate refrigerant system (WP 0263).
END OF TASK
REFRIGERANT LEAKAGE: TEST
00036
Leak test refrigerant system (WP 0263).
END OF TASK
REFRIGERANT SYSTEM: CHARGE
00036
Charge refrigerant system (WP 0263).
END OF TASK
0036-1