TM 5-2410-241-23-2
0060
ETHER VALVE INSTALLATION
00060
1. Install fitting (Figure 14, Item 16) on valve (Figure 14, Item 14).
2. Install valve (Figure 14, Item 14), bracket (Figure 14, Item 15), cap (Figure 14, Item 5), tether (Figure 14,
Item 4), and two bolts (Figure 14, Item 3) on bracket (Figure 14, Item 7).
3. Install housing (Figure 14, Item 1) and screw (Figure 14, Item 2) on bracket (Figure 14, Item 15).
4. Install cap (Figure 14, Item 5) on housing (Figure 14, Item 1).
5. Install new gasket (Figure 14, Item 6) on valve (Figure 14, Item 14).
6. Install bracket (Figure 14, Item 7), clip (Figure 14, Item 10), two washers (Figure 14, Item 9), and nuts (Figure
14, Item 8) on machine.
7. Connect connector (Figure 14, Item 12) to connector (Figure 14, Item 13).
8. Install new tiedown strap (Figure 14, Item 11) on connector (Figure 14, Item 13).
Figure 14. Ether Valve.
0060