Figure 3. Receptacle Cable at Junction Block.
Figure 4. Receptacle and Battery Disconnect Switch Connections.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  903    904    905    906    907  908  909    910    911    912    913  
img
TM 5-2410-241-23-2
0162
INSTALLATION
000162
N OT E
Arctic kit power battery cable shown for machines equipped with arctic kit.
Route cables as noted during removal.
1. Install junction block power cable (Figure 3, Item 5) on machine.
2. Install junction block power cable (Figure 3, Item 5), arctic kit power battery cable (Figure 3, Item 10), fuse
panel power cable (Figure 3, Item 6), new lockwasher (Figure 3, Item 9), and nut (Figure 3, Item 8) on junction
block (Figure 3, Item 11).
3. Position boot (Figure 3, Item 7) on nut (Figure 3, Item 8).
N OT E
Install clamps as noted during removal.
4. Install clamp (Figure 3, Item 2), washer (Figure 3, Item 3), and new locknut (Figure 3, Item 4) on receptacle
ground cable (Figure 3, Item 1) and junction block power cable (Figure 3, Item 5).