BATTERY DISCONNECT SWITCH, RECEPTACLE AND CABLE REPLACEMENT
Figure 2. Receptacle and Battery Disconnect Switch Connections.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  900    901    902    903    904  905  906    907    908    909    910  
img
.
TM 5-2410-241-23-2
0162
REMOVAL
000162
1. Remove key (Figure 1, Item 5) from battery disconnect switch (Figure 1, Item 3).
2. Remove nut (Figure 1, Item 1), two lockwashers (Figure 1, Item 2), and battery disconnect switch (Figure 1,
Item 3) from front battery box cover (Figure 1, Item 4). Discard lockwashers.
3. Remove receptacle cover (Figure 1, Item 6) from receptacle (Figure 1, Item 7).
Figure 1. Battery Disconnect Switch.