Figure 17. Fuse Box Connections.
Figure 2. Power Converter.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1034    1035    1036    1037    1038  1039  1040    1041    1042    1043    1044  
img
. . .
2
TM 5-2410-241-23-2
0177
FIELD MAINTENANCE INSTRUCTIONS
-
POWER CONVERTER REPLACEMENT
0177
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-241-10)
0
(WP 0302, Item 65)
Batteries removed (WP 0155)
0
0
Materials/Parts
Drawing Required
0
0
Rag, Wiping (WP 0303, Item 24)
TM 5-2410-241-24P, Figure 87
0
0
References
Estimated Time to Complete
0
0
2.5 Hr
WP 0295
0
0
REMOVAL
000177
1. Disconnect connector (Figure 1, Item 4) from power converter (Figure 1, Item 1).
2. Remove six bolts (Figure 1, Item 2), washers (Figure 1, Item 3), and power converter (Figure 1, Item 1) from
machine.
Figure 1. Power Converter.
0177
END OF TASK