2
TM 5-2410-241-23-2
FIELD MAINTENANCE INSTRUCTIONS
-
POWER CONVERTER REPLACEMENT
0177
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Condition
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-241-10)
0
(WP 0302, Item 65)
0
0
Materials/Parts
Drawing Required
0
0
Rag, Wiping (WP 0303, Item 24)
TM 5-2410-241-24P, Figure 87
0
0
References
Estimated Time to Complete
0
0
2.5 Hr
WP 0295
0
0
REMOVAL
000177
1. Disconnect connector (Figure 1, Item 4) from power converter (Figure 1, Item 1).
2. Remove six bolts (Figure 1, Item 2), washers (Figure 1, Item 3), and power converter (Figure 1, Item 1) from
machine.
Figure 1. Power Converter.
0177
END OF TASK