HYDRAULIC SYSTEM PRESSURE RELEASE
HYDRAULIC TANK REPLACEMENT

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1078    1079    1080    1081    1082  1083  1084    1085    1086    1087    1088  
img
.
TM 5-2410-241-23-2
0186
HYDRAULIC SYSTEM PRESSURE RELEASE CONTINUED
WARN I N G
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Lubricating/hydraulic oils used in perfomance of maintenance can be very slippery.
r
Immediately wipe up any spills.
Failure to follow these warnings may result in injury or death to personnel.
5. Loosen fill cap (Figure 2, Item 1) to relieve pressure from hydraulic tank (Figure 2, Item 2).
6. If hydraulic fluid is to be drained, remove cap. If fluid drain is not required, tighten fill cap (Figure 2, Item 1)
7. Reinstall fill cap after fluid drain is complete.
Figure 2. Hydraulic System Fill Cap.
0186
END OF TASK
END OF WORK PACKAGE