TM 5-2410-241-23-3
0216
DISASSEMBLY CONTINUED
N OT E
Note orientation and position of fittings to aid assembly.
33. Remove two O-rings (Figure 13, Item 1) from fitting (Figure 13, Item 2). Discard O-rings.
34. Remove nut (Figure 13, Item 10) and elbow (Figure 13, Item 6) from T fitting (Figure 13, Item 8).
35. Remove O-ring (Figure 13, Item 7) from T fitting (Figure 13, Item 8). Discard O-ring.
36. Remove cover and strap (Figure 13, Item 3) from diagnostic port fitting (Figure 13, Item 4).
37. Loosen nut (Figure 13, Item 9) and remove diagnostic port fitting (Figure 13, Item 4) from elbow (Figure 13,
Item 6).
38. Remove O-ring (Figure 13, Item 5) from elbow (Figure 13, Item 6). Discard O-ring.
Figure 13. Fitting Disassembly.