RECEIVER DRYER REPLACEMENT
CLEANING AND INSPECTION

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  480    481    482    483    484  485  486    487    488    489    490  
img
.
TM 5-2410-241-23-3
0240
REMOVAL
000240
WARN I N G
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent
personal injury.
Protective face shield and gloves must always be worn when refrigerant lines are opened,
even if gauges indicate A/C system is empty.
Always use caution when disconnecting fittings Slowly loosen fitting in well-ventilated
.
area.
Do not smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
N OT E
Tag hoses to aid installation.
Clean exterior of hoses before removal to prevent contamination.
1. Disconnect quick disconnect fitting (Figure 1, Item 1) from receiver dryer (Figure 1, Item 2).
2. Disconnect quick disconnect fitting (Figure 1, Item 3) from receiver dryer (Figure 1, Item 2).
3. Remove bolt (Figure 1, Item 5), washer (Figure 1, Item 6), two clamps (Figure 1, Item 4), spacer (Figure 1,
Item 7), and receiver dryer (Figure 1, Item 1) from machine.
Figure 1. Receiver Dryer.
0240
END OF TASK
0240-2