ACCUMULATOR REPLACEMENT
INSTALLATION

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  477    478    479    480    481  482  483    484    485    486    487  
img
. .
TM 5-2410-241-23-3
0239
REMOVAL
000239
N OT E
Tag hoses to aid installation.
Clean exterior of hoses before removal to prevent contamination.
Cap and plug all hoses and lines to prevent contamination and leaks.
1. Disconnect hose assembly (Figure 1, Item 1) from accumulator (Figure 1, Item 3). Remove O-ring (Figure 1,
Item 2) from hose assembly. Discard O-ring.
2. Disconnect hose assembly (Figure 1, Item 8) from accumulator (Figure 1, Item 3). Remove O-ring (Figure 1,
Item 7) from hose assembly. Discard O-ring.
3. Remove two bolts (Figure 1, Item 5), washers (Figure 1, Item 4), two straps (Figure 1, Item 6), and accumulator
(Figure 1, Item 3) from machine.
Figure 1. Accumulator.
0239
END OF TASK
CLEANING AND INSPECTION
000239
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK
0239-2