TM 5-2410-240-23-1
0019
Table 2. Engine Troubleshooting with Codes - Continued.
0019
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0002-05 Cylinder #2 Injector Current
Below Normal Continued
(WP 0283), test for continuity
Replace fuel injector #2
between terminal 1 and termi-
(WP 0077).
Remove jumper wire from termi-
Figure 174) harness connec-
nal H-T1 and terminal H-T2
tor.
Figure 174) at valve cover base.
Verify proper operation of machine
(TM 5-2410-240-10).
fuel injector harness (WP 0104).
Verify proper operation of machine
(TM 5-2410-240-10).
0002-06 Cylinder #2 Injector Current
WARN I N G
Above Normal
Electrical shock hazard. Electronic unit injector system uses 67-
73 Volts. Failure to follow this warning may result in injury to per-
sonnel.
Test Step 1: Test Fuel Injector
and Engine Control Wiring Har-
nesses.
N OT E
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
a connection is found, correct problem and verify that this
diagnostic code is active before performing this procedure.
Tag wiring harnesses to aid installation.
Select engine ECM C6.6 D6K.
2. Start engine or attempt to start
engine (TM 5-2410-240-10).
0001-05, 0002-05, and 0003-05
3. At MSD, check if all three
Diagnostic Codes are Active -
diagnostic codes 0001-05,
Replace engine ECM (WP 0049).
0002-05, and 0003-05 are
Verify proper operation of machine
(TM 5-2410-240-10).