Table 2. Engine Troubleshooting with Codes - Continued.
Table 2. Engine Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  404    405    406    407    408  409  410    411    412    413    414  
img
. . . . . . . . .
TM 5-2410-240-23-1
0019
Table 2. Engine Troubleshooting with Codes - Continued.
0019
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0190-08 Engine Speed Sensor
2. Disconnect engine ECM har-
Abnormal Frequency, Pulse Width,
ness connector E-C1
or Period Continued
(WP 0018, Figure 102) from
engine ECM J2.
3. Using digital multimeter
Continuity - ECM faulty. Replace
(WP 0283), test for continuity
engine ECM (WP 0049).
between E-C4 (WP 0018,
Connect E-C4 (WP 0018,
Figure 105) harness connec-
Figure 105) to engine speed
tor terminal 1, and engine
(crank position) sensor.
ECM harness connector E-C1
Verify proper operation of machine
(WP 0018, Figure 102) termi-
(TM 5-2410-240-10).
nal 10.
No Continuity - Engine control
wiring harness is open. Replace
engine control wiring harness
(WP 0052).
Verify proper operation of machine
(TM 5-2410-240-10).
0253-02 Personality Module Erratic,
1. Connect MSD (WP 0016).
Intermittent, or Incorrect
Select engine ECM C6.6 D6K.
2. Start and run engine (TM 5-
2410-240-10), and verify
0253-02 is active.
Program the engine ECM
3. Verify machine ECM software
(WP 0017). Verify proper operation
part number is correct, refer to
of machine (TM 5-2410-240-10).
ECM Programming
(WP 0017).
0261-11 Engine Timing Offset Fault
1. Connect MSD (WP 0016).
Select engine ECM C6.6 D6K.
0261-11 Active - Adjust timing on
2. Start and run engine (TM 5-
fuel injector pump (WP 0075). Ver-
2410-240-10), and verify
ify proper operation of machine
0261-11 is active.
(TM 5-2410-240-10).
No Active Codes - Return
machine to service.
0262-03 5-Volt Sensor DC Supply
Test Step 1: Test 5-Volt Supply
Voltage Above Normal Code
Circuit.
N OT E
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in the circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct the problem and verify diagnostic
code is active before performing this procedure.
Tag wiring harnesses to aid installation.