Table 2. Engine Troubleshooting with Codes - Continued.
Table 2. Engine Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  409    410    411    412    413  414  415    416    417    418    419  
img
. . . . . . . . .
TM 5-2410-240-23-1
0019
Table 2. Engine Troubleshooting with Codes - Continued.
0019
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0262-04 5 Volt Sensor DC Supply
Test Step 2: Test Harness.
Voltage Below Normal Code Con-
1. Turn ignition switch and bat-
tinued
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect engine ECM har-
ness connector E-C1
(WP 0018, Figure 102) from
engine ECM J2.
3. Using digital multimeter
Continuity - Engine control wiring
(WP 0283), test for continuity
harness is shorted. Replace
between the following 5-volt
engine control wiring harness
supply circuits:
(WP 0052).
a. Engine ECM harness
Connect FF-C4 (WP 0018,
connector E-C1
Figure 150) to prime pump temper-
(WP 0018, Figure 102)
ature sensor.
terminal 46 and all other
Verify proper operation of machine
E-C1 terminals.
(TM 5-2410-240-10).
b. Engine ECM harness con-
No Continuity - Proceed to step 4.
nector E-C1 (WP 0018,
Figure 102) terminal 47
and all other E-C1 termi-
nals.
c.
Engine ECM harness con-
nector E-C1 (WP 0018,
Figure 102) terminal 48
and all other E-C1 termi-
nals.
4. Using digital multimeter
Continuity - Engine control wiring
(WP 0283), test for continuity
harness is shorted. Replace
between the following 5-volt
engine control wiring harness
supply circuits and ground:
(WP 0052).
a. Engine ECM harness
Connect FF-C4 (WP 0018,
connector E-C1
Figure 150) to prime pump temper-
(WP 0018, Figure 102)
ature sensor.
terminal 46 and ground.
Verify proper operation of machine
b. Engine ECM harness con- (TM 5-2410-240-10).
nector E-C1 (WP 0018,
No Continuity - Proceed to step 5.
Figure 102) terminal 47
and ground.
c.
Engine ECM harness con-
nector E-C1 (WP 0018,
Figure 102) terminal 48
and ground.
0019-95