TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1708-03 Proportional Sole-
2. Turn ignition switch and battery
noid Valve (Right Drive
disconnect switch to OFF position
Motor) Voltage Above Nor-
(TM 5-2410-240-10).
mal - Continued
3. Disconnect pump harness RH
drive motor solenoid connector
CH-C5 (WP 0018, Figure 84) from
RH drive motor solenoid.
4. Disconnect chassis harness to
platform harness connector CH-
C1 (WP 0018, Figure 81) from
platform harness to chassis har-
ness connector PL-C18 (WP
0018, Figure 226).
5. Using digital multimeter (WP
Continuity - Proceed to step 6.
0283), test for continuity between
No Continuity - Replace chassis har-
pin 26 on chassis harness to plat-
ness (WP 0153, WP 0154). Ensure all
form harness connector CH-C1
harness connectors are reconnected.
(WP 0018, Figure 81) and pin 1
Verify proper operation of machine
on pump harness RH drive motor
(TM 5-2410-240-10).
solenoid connector CH-C5 (WP
0018, Figure 84).
6. Using digital multimeter (WP
No Continuity - Proceed to step 7.
0283), test for continuity between
Continuity - Replace chassis harness
pin 26 on chassis harness to plat-
(WP 0153, WP 0154). Ensure all har-
form harness connector CH-C1
ness connectors are reconnected.
(WP 0018, Figure 81) and all
Verify proper operation of machine
other pins on chassis harness to
(TM 5-2410-240-10).
platform harness connector CH-
C1 (WP 0018, Figure 81).
7. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
8. Disconnect platform harness
ECM J2 connector PL-C5 (WP
0018, Figure 218) from machine
ECM (WP 0147, WP 0149).
9. Using digital multimeter (WP
Continuity - Proceed to step 10.
0283), test for continuity between
No Continuity - Replace platform wir-
pin 59 on platform harness ECM
ing harness (WP 0150, WP 0155).
J1 connector PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) and pin 26 on plat-
reconnected. Verify proper operation
form harness to chassis harness
of machine (TM 5-2410-240-10).
connector PL-C18 (WP 0018, Fig-
ure 226).