Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  568    569    570    571    572  573  574    575    576    577    578  
img
. . . . . . . . . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1708-05 Proportional Sole-
5. Check for diagnostic codes (WP
1708-05 Code Active - Proceed to
noid Valve (Right Drive
0013).
step 6.
Motor) Current Below Nor-
1708-06 Code Active - Replace RH
mal - Continued
drive motor solenoid (WP 0128).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
6. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
7. Disconnect chassis harness to
platform harness connector CH-
C1 (WP 0018, Figure 81) from
platform harness to chassis har-
ness connector PL-C18 (WP
0018, Figure 226).
8. Using digital multimeter (WP
Continuity - Proceed to step 9.
0283), test for continuity between
No Continuity - Replace chassis har-
pin 26 on chassis harness to plat-
ness (WP 0153, WP 0154). Ensure all
form harness connector CH-C1
harness connectors are reconnected.
(WP 0018, Figure 81) and pin 1
Verify proper operation of machine
on pump harness RH drive motor
(TM 5-2410-240-10).
solenoid connector CH-C5 (WP
0018, Figure 84).
9. Using digital multimeter (WP
Continuity - Proceed to step 10.
0283), test for continuity between
No Continuity - Replace chassis har-
pin 17 on chassis harness to plat-
ness (WP 0153, WP 0154). Ensure all
form harness connector CH-C1
harness connectors are reconnected.
(WP 0018, Figure 81) and pin 2
Verify proper operation of machine
on pump harness RH drive motor
(TM 5-2410-240-10).
solenoid connector CH-C5 (WP
0018, Figure 84).
10. Using digital multimeter (WP
No Continuity - Proceed to step 11.
0283), test for continuity between
Continuity - Replace chassis harness
pin 26 on chassis harness to plat-
(WP 0153, WP 0154). Ensure all har-
form harness connector CH-C1
ness connectors are reconnected.
(WP 0018, Figure 81) and all
Verify proper operation of machine
other pins on chassis harness to
(TM 5-2410-240-10).
platform harness connector CH-
C1 (WP 0018, Figure 81).
11. Disconnect platform harness
ECM J1 connector PL-C4 (WP
0018, Figure 217) from machine
ECM (WP 0147, WP 0149).
0020-125


Privacy Statement