TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
N OT E
1708-06 Proportional Sole-
noid Valve (Right Drive
Always inspect harness connectors that are involved in circuit. Poor
Motor) Current Above Nor-
connections can often be the cause of an electrical circuit problem.
mal
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1708-06 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness RH
RH drive motor solenoid.
4. Check for diagnostic codes (WP
1708-06 Code Active - Proceed to
step 5.
1708-05 Code Active - Replace LH
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
5. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
6. Disconnect chassis harness to
platform harness connector CH-
platform harness to chassis har-
ness connector PL-C18 (WP