• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
BATTERY CLEANING
Figure 4. Ground Cable to Disconnect Switch.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1301    1302    1303    1304    1305  1306  1307    1308    1309    1310    1311  
img
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION
00030
Test Step 1 - Ground Cables
00030
1. Verify all battery cable connections are clean and tight.
2. Turn battery disconnect switch to ON position (TM 5-2410-240-10).
3. Using digital multimeter, measure voltage between positive post (Figure 4, Item 1) and negative post (Figure 4,
Item 2) of battery (Figure 4, Item 7). Monitor and record voltage.
4. Using digital multimeter, measure voltage between positive post (Figure 4, Item 1) and battery cable
(Figure 4, Item 3). Voltage should be less than 1-Volt from value recorded in step 3.
a. If voltage is more than 1-Volt from value recorded in step 3, replace battery cable (Figure 4, Item 3) from
battery (Figure 4, Item 7) to disconnect switch (Figure 4, Item 4) (WP 0142).
b. If voltage is less than 1-Volt from value recorded in step 3, machine negative battery cables are OK. Pro-
ceed to next step to check other ground cables.
5. Using digital multimeter, measure voltage between positive post (Figure 4, Item 1) and disconnect switch termi-
nal (Figure 4, Item 5). Voltage should be less than 1-Volt from value recorded in step 3.
a. If voltage is more than 1-Volt from value recorded in step 3, replace disconnect switch (Figure 4, Item 4)
(WP 0142).
b. If voltage is less than 1-Volt from value recorded in step 3, machine negative battery cables are OK. Pro-
ceed to next step to check other ground cables.
0030-6