BATTERY AND CABLES INSPECTION
Figure 5. Starter Ground Cable.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1302    1303    1304    1305    1306  1307  1308    1309    1310    1311    1312  
img
.
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 1 - Ground Cables Continued
00030
6. Using digital multimeter, measure voltage between positive post (Figure 4, Item 1) and machine ground. Volt-
age should be less than 1-Volt from value recorded in step 3.
a. If voltage is more than 1-Volt from value recorded in step 3, replace ground cable (Figure 4, Item 6) from
disconnect switch (Figure 4, Item 4) to frame (WP 0142).
b. If voltage is less than 1-Volt from value recorded in step 3, machine negative battery cables are OK. Pro-
ceed to next step to check other ground cables.
Figure 4. Ground Cable to Disconnect Switch.
0030
0030-7