TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 2 - Positive Cables - Continued
00030
2. Remove front floor plate (WP 0209).
3. Using digital multimeter, measure voltage between junction box positive post (Figure 9, Item 1) and machine
ground. Voltage should be less than 1-Volt from value recorded in step 1.
a. If voltage is more than 1-Volt from value recorded in step 1, replace positive battery cable (Figure 9, Item 1)
between battery (Figure 9, Item 3) and junction box (Figure 9, Item 2) (WP 0144).
b. If voltage is less than 1-Volt from value recorded in step 1, proceed to next step.
Figure 9. Battery to Junction Box.
0030