Figure 9. Battery to Junction Box.
Figure 11. Junction Box to Fuse Panel.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1308    1309    1310    1311    1312  1313  1314    1315    1316    1317    1318  
img
.
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 2 - Positive Cables - Continued
00030
4. Using digital multimeter, measure voltage between starter terminal (Figure 10, Item 2) and machine ground.
Voltage should be less than 1-Volt from value recorded in step 1.
a. If voltage is more than 1-Volt from value recorded in step 1, replace positive battery cable (Figure 10,
Item 3) between junction box (Figure 10, Item 4) and starter (Figure 10, Item 1) (WP 0046).
b. If voltage is less than 1-Volt from value recorded in step 1, proceed to next step.
Figure 10. Junction Box to Starter.