• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 13. Alternator to Fuse Panel Cable.
BATTERY CHARGING OUT OF MACHINE

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1312    1313    1314    1315    1316  1317  1318    1319    1320    1321    1322  
img
.
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 2 - Positive Cables - Continued
00030
9. Release two latches (Figure 14, Item 2) from arctic heater battery cover (Figure 14, Item 1).
10. With an assistant remove arctic heater battery cover (Figure 14, Item 1).
11. Disconnect arctic heater positive battery cable (Figure 14, Item 3) from arctic heater batteries (Figure 14,
Item 5).
12. Using digital multimeter, measure voltage between arctic heater positive battery cable terminal (Figure 14,
Item 3) of arctic heater battery (Figure 14, Item 5) and negative post (Figure 14, Item 4) of arctic heater battery.
Voltage should be less than 1-Volt from value recorded in step 1.
a. If voltage is more than 1-Volt from value recorded in step 1 replace arctic heater positive battery cable
(Figure 14, Item 6) (WP 0282).
b. If voltage is less than 1-Volt from value recorded in step 1, positive battery cables and positive alternator
cables are OK.
13. Connect arctic heater positive battery cable (Figure 14, Item 3) to arctic heater battery (Figure 14, Item 5).
14. With an assistant, install arctic heater battery cover (Figure 14, Item 1), and install two latches (Figure 14,
Item 2) on arctic heater battery cover (Figure 14, Item 1).
Figure 14. Arctic Heater Positive Battery Cable.
0030
END OF TASK
0030-17