Figure 5. Starter Ground Cable.
Figure 7. Arctic Heater Negative Battery Cable.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1304    1305    1306    1307    1308  1309  1310    1311    1312    1313    1314  
img
.
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 1 - Ground Cables Continued
00030
8. Remove NATO slave receptacle cover (Figure 6, Item 1) from NATO slave receptacle (Figure 6, Item 3).
9. Using digital multimeter, measure voltage between positive post (Figure 6, Item 5) of battery (Figure 6, Item 6)
and outer contact (Figure 6, Item 2) (negative side) of NATO slave receptacle (Figure 6, Item 3). Voltage
should be less than 1-Volt from value recorded in step 3.
a. If voltage is more than 1-Volt from value recorded in step 3, replace NATO negative cable (Figure 6,
Item 4) to starter (WP 0046).
b. If voltage is less than 1-Volt from value recorded in step 3, install NATO slave receptacle cover (Figure 6,
Item 1) and proceed to next step.
Figure 6. Negative Cable of NATO Slave Receptacle.
0030
0030-9