Figure 6. Negative Cable of NATO Slave Receptacle.
Figure 8. Positive and Negative Battery Voltage Test.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1305    1306    1307    1308    1309  1310  1311    1312    1313    1314    1315  
img
.
TM 5-2410-240-23-1
0030
BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 1 - Ground Cables Continued
00030
10. Release two latches (Figure 7, Item 2) on arctic heater battery cover (Figure 7, Item 1).
11. With an assistant, remove arctic heater battery cover (Figure 7, Item 1) from machine.
12. Disconnect arctic heater negative battery cable (Figure 7, Item 3) at arctic battery (Figure 7, Item 4).
13. Using digital multimeter, measure voltage between arctic heater negative battery cable (Figure 7, Item 3) and
positive post (Figure 7, Item 5) of battery (Figure 7, Item 6). Voltage should be less than 1-Volt from value
recorded in step 3.
a. If voltage is more than 1-Volt from value recorded in step 3, replace arctic heater negative battery cable
(Figure 7, Item 3) (WP 0282).
b. If voltage is less than 1-Volt from value recorded in step 3, proceed to Test Step 2.
14. With an assistant, install arctic heater battery cover (Figure 7, Item 1), and install two latches (Figure 7, Item 2)
on arctic heater battery cover.
Figure 7. Arctic Heater Negative Battery Cable.