BATTERY AND CABLES INSPECTION CONTINUED
00030
Test Step 2 - Positive Cables
00030
1. Using digital multimeter, measure voltage between positive post (Figure 8, Item 1) and negative post (Figure 8,
Item 2) of the batteries (Figure 8, Item 3). Monitor and record voltage.
Figure 8. Positive and Negative Battery Voltage Test.
0030
0030-11