Figure 27. Mechanical Adjustment.
Figure 29. Hydraulic Adjustment.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1353    1354    1355    1356    1357  1358  1359    1360    1361    1362    1363  
img
.
TM 5-2410-240-23-1
0031
PISTON PUMP NEUTRAL ADJUSTMENT CONTINUED
Hydraulic Adjustment
00031
1. For left hydrostatic pump Figure 28, Item 3), install pressure gauge on X1 port (Figure 28, Item 4) and X2 port
(Figure 28, Item 5).
2. For right hydrostatic pump (Figure 28, Item 1), install hose between X1 port (Figure 28, Item 2) and X2 port
(Figure 28, Item 6).
Figure 28. X1 and X2 Test Port.
0031
0031-39