Figure 2. Pump.
PUMP COUPLING REPLACEMENT - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  475    476    477    478    479  480  481    482    483    484    485  
img
.
TM 5-2410-240-23-2
0096
PUMP COUPLINGFLYWHEEL INSTALLATION
00096
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of clean up rags IAW local policy
and ordinances. Failure to follow this warning may cause injury to personnel.
1. Apply sealing compound on threads of four bolts (Figure 3, Item 1).
N OT E
Install coupling as noted during removal.
2. Install coupling (Figure 3, Item 2) and four bolts (Figure 3, Item 1) to flywheel (Figure 3, Item 3). Torque bolts to
155 lb-ft (210 Nm).
Figure 3. Flywheel.
0096
END OF TASK
0096-3