9. Master link (Figure 11, Item 1) is properly installed when there is 0.06 in. (1.5 mm) gap between master link
(Figure 11, Item 1) and inside track link (Figure 11, Item 2). Master link (Figure 11, Item 4) and pin (Figure 11,
Item 3) should be flush.
Figure 11. Master Link Installation.