TRACK SERVICE - Continued
Figure 13. Track Support.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  612    613    614    615    616  617  618    619    620    621    622  
img
.
TM 5-2410-240-23-2
0112
INSTALLATION CONTINUED
9. Master link (Figure 11, Item 1) is properly installed when there is 0.06 in. (1.5 mm) gap between master link
(Figure 11, Item 1) and inside track link (Figure 11, Item 2). Master link (Figure 11, Item 4) and pin (Figure 11,
Item 3) should be flush.
Figure 11. Master Link Installation.
0112
0112-12