Figure 28. Positive Cable.
LEFT HYDROSTATIC DRIVE PISTON PUMP SERVICE - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  787    788    789    790    791  792  793    794    795    796    797  
img
.
TM 5-2410-240-23-2
0133
INSTALLATION CONTINUED
N OT E
Install electrical connections as noted during removal.
42. Install cable (Figure 29, Item 8), washer (Figure 29, Item 6), and bolt (Figure 29, Item 7), on frame (Figure 29,
Item 12).
43. Install clamp (Figure 29, Item 9), washer (Figure 29, Item 10), and bolt (Figure 29, Item 11) on cable
(Figure 29, Item 8) and frame (Figure 29, Item 12).
44. Install two cables (Figure 29, Item 2) and nut (Figure 29, Item 1) on starter (Figure 29, Item 5).
45. Position cover (Figure 29, Item 4) over nut (Figure 29, Item 1) and install new tiedown strap (Figure 29, Item 3)
on cover.
Figure 29. Starter Cables.
0133
END OF TASK
0133-26