Figure 2. Tube Retaining Hardware on Left Hydrostatic Drive Piston Pump.
Figure 5. Tube on Left and Right Hydrostatic Drive Piston Pump and Transmission Control Manifold.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  792    793    794    795    796  797  798    799    800    801    802  
img
.
TM 5-2410-240-23-2
0134
REMOVAL CONTINUED
6. Remove nut (Figure 3, Item 5), washer (Figure 3, Item 4), bolt (Figure 3, Item 1), and washer (Figure 3, Item 2)
from two clamps (Figure 3, Item 3). Position clamps aside.
Figure 3. Tube Retaining Hardware on Right Hydrostatic Drive Piston Pump.
0134
N OT E
Tag and mark tube and fittings to aid installation.
Cap or plug tube and fittings.
7. Loosen two tube nuts (Figure 4, Items 1 and 5) and disconnect tube (Figure 4, Item 3) from fitting (Figure 4,
Item 4) and transmission control manifold (Figure 4, Item 2). Remove tube from machine.
Figure 4. Tube on Right Hydrostatic Drive Piston Pump and Transmission Control Manifold.