Figure 9. Pump Mounting.
Figure 10. Pump Solenoid Connections.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  824    825    826    827    828  829  830    831    832    833    834  
img
TM 5-2410-240-23-2
0135
INSTALLATION
000135
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support. Ensure lifting
device used is in good condition and of suitable load capacity. Keep clear of heavy parts
supported only by lifting device. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Pump weighs approximately 158 lb (72 kg).
1. Attach new O-ring (Figure 9, Item 4) on pump (Figure 9, Item 1).
2. Attach suitable lifting device to pump (Figure 9, Item 1).
3. Using lifting device, install pump (Figure 9, Item 1), four washers (Figure 9, Item 7) and bolts (Figure 9, Item 6)
on machine.
4. Remove lifting device from pump (Figure 9, Item 1).
5. Install bracket (Figure 9, Item 5), four spacers (Figure 9, Item 3) and bolts (Figure 9, Item 2) on pump
(Figure 9, Item 1).
0135-11