Figure 7. Pump Support.
Figure 9. Pump Mounting.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  822    823    824    825    826  827  828    829    830    831    832  
img
.
TM 5-2410-240-23-2
0135
REMOVAL CONTINUED
25. Remove and discard two tiedown straps (Figure 8, Item 3).
N OT E
Tag electrical connectors to aid installation.
26. Disconnect two connectors (Figure 8, Item 1) from solenoids (Figure 8, Item 2).
Figure 8. Pump Solenoid Connections.
0135
0135-9