Figure 8. Pump Solenoid Connections.
RIGHT HYDROSTATIC DRIVE PISTON PUMP SERVICE (WITH RIPPER) - Continued

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  823    824    825    826    827  828  829    830    831    832    833  
img
.
TM 5-2410-240-23-2
0135
REMOVAL CONTINUED
27. Remove four bolts (Figure 9, Item 2), spacers (Figure 9, Item 3) and bracket (Figure 9, Item 5) from pump
(Figure 9, Item 1).
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support. Ensure lifting
device used is in good condition and of suitable load capacity. Keep clear of heavy parts
supported only by lifting device. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Pump weighs approximately 158 lb (72 kg).
28. Attach suitable lifting device to pump (Figure 9, Item 1).
29. Using lifting device, remove four bolts (Figure 9, Item 6), washers (Figure 9, Item 7) and pump (Figure 9,
Item 1) from machine.
30. Place pump (Figure 9, Item 1) on flat level surface. Remove lifting device from pump.
31. Remove O-ring (Figure 9, Item 4) from pump (Figure 9, Item 1). Discard O-ring.
Figure 9. Pump Mounting.
0135
END OF TASK
CLEANING AND INSPECTION
000135
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
0135-10