Figure 10. Pump Solenoid Connections.
Figure 12. Charge Pressure Hose.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  826    827    828    829    830  831  832    833    834    835    836  
img
.
TM 5-2410-240-23-2
0135
INSTALLATION CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support. Ensure lifting
device used is in good condition and of suitable load capacity. Keep clear of heavy parts
supported only by lifting device. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Pump support weighs approximately 85 lb (39 kg).
8. With assistance, install pump support (Figure 11, Item 1), 10 washers (Figure 11, Item 2), and bolts (Figure 11,
Item 3) on machine.
N OT E
Install tiedown straps as noted during removal.
9. Install three tiedown straps (Figure 11, Item 4) on harness (Figure 11, Item 5).
Figure 11. Pump Support.