Figure 12. Charge Pressure Hose.
Figure 14. Pilot Hose.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  828    829    830    831    832  833  834    835    836    837    838  
img
.
TM 5-2410-240-23-2
0135
INSTALLATION CONTINUED
N OT E
Install hoses as noted during removal.
11. Install four new O-rings (Figure 13, Item 7) on two fittings (Figure 13, Items 3 and 9).
12. Install two fittings (Figure 13, Items 3 and 9) and coupling (Figure 13, Item 5) on pump (Figure 13, Item 8).
13. Connect hose (Figure 13, Item 4) on coupling (Figure 13, Item 5).
14. Install hoses (Figure 13, Item 1 and 6) on fittings (Figure 13, Item 3 and 9) and tighten tube nuts (Figure 13,
Items 2 and 10).
Figure 13. Pump Hose Installation.
0135
0135-15