RIGHT HYDROSTATIC DRIVE PISTON PUMP SERVICE (WITH RIPPER) - Continued
Figure 11. Pump Support.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  825    826    827    828    829  830  831    832    833    834    835  
img
.
TM 5-2410-240-23-2
0135
INSTALLATION CONTINUED
N OT E
Install electrical connectors as tagged during removal.
6. Connect two connectors (Figure 10, Item 1) on solenoids (Figure 10, Item 2).
N OT E
Install tiedown straps as noted during removal.
7. Install two new tiedown straps (Figure 10, Item 3) on harness.
Figure 10. Pump Solenoid Connections.
0135
0135-12