Figure 2. Winch Solenoid Harness and Retaining Hardware.
Figure 1. Backup Alarm Connector and Mounting Plate.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  843    844    845    846    847  848  849    850    851    852    853  
img
.
6
TM 5-2410-240-23-2
0138
FIELD MAINTENANCE
-
BACKUP ALARM REPLACEMENT
0
138
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Equipment Conditions
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-240-10)
0
(WP 0289, Item 51)
Right rear access cover removed
0
(WP 0191)
0
Materials/Parts
0
Drawings Required
Rag, wiping (WP 0290, Item 21)
0
0
Tag, marker (WP 0290, Item 30)
TM 5-2410-240-24P, Figure 65
0
0
Tiedown strap (WP 0290, Item 31)
0
Estimated Time to Complete
0
References
0.3 Hr
0
0
WP 0282
0
0138-1