BACKUP ALARM REPLACEMENT
Figure 2. Backup Alarm Harness and Grommet.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  844    845    846    847    848  849  850    851    852    853    854  
img
.
TM 5-2410-240-23-2
0138
REMOVAL
000138
1. Remove tiedown strap (Figure 1, Item 7) from backup alarm connector (Figure 1, Item 2) and clip (Figure 1,
Item 8). Discard tiedown strap.
2. Remove tiedown strap (Figure 1, Item 4) from clip (Figure 1, Item 5). Discard tiedown strap.
N OT E
Tag and mark electrical connectors to aid installation.
3. Disconnect backup alarm connector (Figure 1, Item 2) from chassis harness connector (Figure 1, Item 3).
4. Remove two bolts (Figure 1, Item 1), washers (Figure 1, Item 10), and clip (Figure 1, Item 6) from mounting
plate (Figure 1, Item 9).
N OT E
Grommet retains backup alarm harness on machine. Grommet must be removed before
removing backup alarm from machine.
5. Position mounting plate (Figure 1, Item 9) aside to access grommet.
Figure 1. Backup Alarm Connector and Mounting Plate.