Figure 1. Backup Alarm Connector and Mounting Plate.
Figure 4. Backup Alarm, Mounting Plate, and Grommet.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  845    846    847    848    849  850  851    852    853    854    855  
img
.
TM 5-2410-240-23-2
0138
REMOVAL CONTINUED
6. Remove grommet (Figure 2, Item 1), backup alarm harness (Figure 2, Item 2), and backup alarm (Figure 2,
Item 3) from machine (Figure 2, Item 4).
Figure 2. Backup Alarm Harness and Grommet.
0138
7. Remove grommet (Figure 3, Item 4) from backup alarm harness (Figure 3, Item 3).
8. Remove bolt (Figure 3, Item 5), washer (Figure 3, Item 6), and backup alarm (Figure 3, Item 1) from mounting
plate (Figure 3, Item 2).
Figure 3. Backup Alarm, Mounting Plate, and Grommet.
0138
END OF TASK
CLEANING AND INSPECTION
000138
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK