Figure 11. Harness Grounds.
Figure 15. Harness Connector.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  930    931    932    933    934  935  936    937    938    939    940  
img
.
TM 5-2410-240-23-2
0147
INSTALLATION CONTINUED
7. Install inner bracket (Figure 13, Item 3), outer bracket (Figure 13, Item 4), three washers (Figure 13, Item 2),
and four nuts (Figure 13, Item 1) on studs (Figure 13, Item 5).
Figure 13. Machine ECM Retaining Hardware.
0147
N OT E
Install electrical connectors as noted during removal.
8. Connect two harness connectors (Figure 14, Item 5) to machine ECM (Figure 14, Item 4) and tighten screws
(Figure 14, Item 2).
9. Install caps (Figure 14, Item 3) on nut (Figure 14, Item 1).
Figure 14. Machine ECM and Harness Connectors.
0147
0147-10