TM 5-2410-240-23-2
0148
REMOVAL
000148
1. Record all diagnostic codes and save equipment ECM configuration data (WP 0017).
N OT E
Tag and mark electrical connectors to aid installation.
3. Loosen screw (Figure 1, Item 4) and disconnect harness connector (Figure 1, Item 5) from equipment ECM
(Figure 1, Item 2).
4. Position harness (Figure 1, Item 6) aside.
5. Remove three bolts (Figure 1, Item 7), washers (Figure 1, Item 8), equipment ECM (Figure 1, Item 2), and
mounting bracket (Figure 1, Item 1) from machine (Figure 1, Item 3).
Figure 1. Equipment ECM, Harness Connector, and Retaining Hardware.