1. Record all diagnostic codes and save equipment ECM configuration data (WP 0017).
2. Remove machine ECM (WP 0147 and WP 0149).
N OT E
Tag and mark electrical connectors to aid installation.
3. Loosen screw (Figure 1, Item 4) and disconnect harness connector (Figure 1, Item 5) from equipment ECM
(Figure 1, Item 2).
4. Position harness (Figure 1, Item 6) aside.
5. Remove three bolts (Figure 1, Item 7), washers (Figure 1, Item 8), equipment ECM (Figure 1, Item 2), and
mounting bracket (Figure 1, Item 1) from machine (Figure 1, Item 3).