MACHINE ECM SERVICE (WITH WINCH)
Figure 2. Machine ECM, Harness Connectors, and Retaining Hardware.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  938    939    940    941    942  943  944    945    946    947    948  
img
. .
TM 5-2410-240-23-2
0149
REMOVAL
000149
1. Record all diagnostic codes and save machine ECM configuration data (WP 0017).
2. Remove batteries (WP 0142).
N OT E
Note location of tiedown straps to aid installation.
Tag and mark electrical connectors to aid installation.
3. Remove tiedown strap (Figure 1, Item 2) from platform harness (Figure 1, Item 3) and winch solenoid harness
(Figure 1, Item 1).
4. Unlock and disconnect platform harness (Figure 1, Item 3) from winch solenoid harness (Figure 1, Item 1).
Figure 1. Platform Harness and Winch Solenoid Harness.
0149
0149-2