Figure 8. Outlet Manifold.
Figure 10. Valve Solenoid Cover.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  193    194    195    196    197  198  199    200    201    202    203  
img
.
TM 5-2410-240-23-3
0196
DISASSEMBLY CONTINUED
C AU T I O N
Mark each valve to identify its location to aid installation. Valves installed in the incorrect
order may cause damage to equipment.
5. Remove ripper control valve (Figure 9, Item 5) from bolts (Figure 9, Item 4).
N OT E
Note location and size of O-rings to aid installation.
6. Remove two fittings (Figure 9, Item 1) and four O-rings (Figure 9, Item 2) from ripper control valve (Figure 9,
Item 5). Discard O-rings.
N OT E
During removal, O-rings may stick to either side of valve face.
Note location and size of O-rings to aid installation.
7. Remove six O-rings (Figure 9, Item 3) from ripper control valve (Figure 9, Item 5). Discard O-rings.
Figure 9. Ripper Control Valve.