TM 5-2410-240-23-3
0196
DISASSEMBLY CONTINUED
29. Remove four bolts (Figure 21, Item 4) from inlet manifold (Figure 21, Item 2).
N OT E
Note location and size of O-rings to aid installation.
30. Remove three fittings (Figure 21, Item 1) and six O-rings (Figure 21, Item 5) from inlet manifold
(Figure 21, Item 2). Discard O-rings.
N OT E
During removal, O-rings may stick to either side of valve face.
Note location and size of O-rings to aid installation.
31. Remove six O-rings (Figure 21, Item 3) from inlet manifold (Figure 21, Item 2). Discard O-rings.
Figure 21. Inlet Manifold.
0196
END OF TASK
CLEANING AND INSPECTION
000196
Clean and inspect all mechanical components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK