Figure 1. Messenger Mounting.
Figure 2. Power Converter.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  387    388    389    390    391  392  393    394    395    396    397  
img
. . . . . .
2
TM 5-2410-240-23-3
0216
FIELD MAINTENANCE
-
POWER CONVERTER REPLACEMENT
0216
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Conditions
0
0
Tool Kit, General Mechanic's
Machine parked (TM 5-2410-240-10)
0
(WP 0289, Item 51)
0
Drawings Required
0
Materials/Parts
TM 5-2410-240-24P, Figure 104
0
0
Rag, wiping (WP 0290, Item 21)
0
Estimated Time to Complete
0
Tiedown strap (WP 0290, Item 31)
0
0.5 Hr
0
References
0
WP 0282
0
REMOVAL
000216
N OT E
Tag and mark electrical connector to aid installation.
1. Disconnect electrical connector (Figure 1, Item 2) from power converter (Figure 1, Item 1).
2. Remove two bolts (Figure 1, Item 3), washers (Figure 1, Item 4), and power converter (Figure 1, Item 1) from
machine.
Figure 1. Power Converter.
0216
END OF TASK