Figure 31. Brush Guard and Cover.
Figure 2. Right Side Panel Insulation Foam.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  545    546    547    548    549  550  551    552    553    554    555  
img
. . . . . . . . . . . .
6
TM 5-2410-240-23-3
0230
FIELD MAINTENANCE
-
INSULATION FOAM REPLACEMENT
02
30
Fuse Panel Cover Insulation Removal, Right Side Panel and Cover Insulation Removal, Cleaning and
Inspection, Surface Preparation, Fit Check, Right Side Panel and Cover Insulation Installation, Fuse
Panel Cover Insulation Installation
INITIAL SETUP
Tools and Special Tools
References
0
0
Tool Kit, General Mechanic's
WP 0235
0
(WP 0289, Item 51)
WP 0241
0
0
Gloves, Rubber (S0208) (WP 0289, Item 53)
WP 0282
0
0
Goggles (S0209) (WP 0289, Item 53)
0
Equipment Conditions
0
Materials/Parts
Machine parked (TM 5-2410-240-10)
0
0
Cleaning compound, solvent, type III
Drawings Required
(WP 0290, Item 6)
0
0
TM 5-2410-240-24P, Figure 107
Detergent, general purpose, liquid
0
(WP 0290, Item 8)
0
Estimated Time to Complete
0
Isopropyl alcohol (WP 0290, Item 12)
0
1.0 Hr
0
Rag, wiping (WP 0290, Item 21)
0
FUSE PANEL COVER INSULATION REMOVAL
000230
1. Remove three bolts (Figure 1, Item 3), washers (Figure 1, Item 2), and fire extinguisher bracket (Figure 1,
Item 1) from fuse panel cover (Figure 1, Item 4).
2. Remove insulation (Figure 1, Item 5) from fuse panel cover (Figure 1, Item 4) by pulling insulation away from
fuse panel cover.
Figure 1. Fuse Panel Cover Insulation Foam.
0230
END OF TASK
0230-1